The passive house: insulate, seal, recover
Make the envelope so well insulated and airtight, and recover so much heat from the exhaust air, that the building needs almost no active heating.
heating ≤ 15 kWh/m²·a · airtightness n₅₀ ≤ 0.6 h⁻¹ · heat recovery ≥ 75%
The Passivhaus standard is defined by performance rather than form. The first passive houses, a terrace of four at Darmstadt-Kranichstein (1990–91), used about a tenth of the heating energy of a typical German house of the time. Their recipe (very thick insulation without thermal bridges, triple glazing, an airtight envelope, mechanical ventilation with heat recovery and a sensible use of solar gain) has since been applied to schools, offices and blocks of flats.